1kW Fuel Cell T-Series
This kW fuel cell stack is the entry-level product in the T Series of fuel cell stacks which are primarily geared towards stationary applications. While this fuel cell stack can be used in a stationary setting like off-grid living, it is focused more on remote commercial locations. Cellular tower sites as well as marine and rail monitoring sites often are located in rural areas, and it is these rural locations that this fuel cell stack is built for. Another benefit to the T Series is that the fuel cells use hydrogen to create energy, which reduces the amount of space that needs to be enclosed since hydrogen is weather agnostic. There is no need for any special structures or accommodations needed to handle a hazardous substance, like diesel, because hydrogen is non-toxic and environmentally friendly.
1000W Fuel Cell Stack T Series
Additional Information
T Series fuel cell systems typically come with a controller, FC connector, RS232 cable, FC +/- cables, output +/- cables, pressure regulator, 6mm PTFE tube, Ferrule Connectors, and a hydrogen sensor.
Customers are required to fill out quote request forms for this fuel cell stack, since Horizon carries a limited number of these at any given time. By submitting the form, we will be able to set proper delivery expectations as well as work with you to create a package to ensure you have all of the fuel cell stack accessories in order to facilitate project development.
List of T-1000 components:
1 x 1000W fuel cell stack
1 x 1000W controller
1 x fuel cell connector
1 x RS232 cable
1 x FC +/- cables
1 x pressure regulator
2 x 6mm PTFE tube (1m)
20 x ferrule connectors
1 x hydrogen sensor
1000W Fuel Cell Stack T Series Quick Product Facts
Hydrogen Pressure
Hydrogen must be fed into the fuel cell stack at a pressure of 0.55 to 0.75bar.
Ambient Temperature
The fuel cell stack operates best in a temperature ranging from 0 to 40° C.
FC Stack Weight
The stack (including fan and casing) weighs 40lbs / 18kg.
System Efficiency
At peak power the efficiency of the system is 42%.
Hydrogen Purity
A fuel of gaseous hydrogen at a minimum purity level of 99.995% is required.
Voltage Output
The voltage can be adjusted to between 43.2 and 57.6 volts direct current.